Autodesk Inventor Translation Report
Source File: W:\Modular\CFLC\HW\Inventor\CFLC-700-4000to12000-160HW.ipt
Wednesday, 2/14/2018 (7:44:56 AM)
Published File: W:\Modular\CFLC\HW\Exports\CFLC-700-12000-160HW-OLD.adsk
Component Type: No classification
Workflow Type: BIM building components Number Of Connections: 8 succeed, 0 fail
Translation Time: 0:00:11.000 Number Of Faces: 2575
Sending System: Inventor 2017.3 Complexity Rating: High
Units: inch Bounding Box Size: 69.125 in x 125.300 in x 148.611 in
Contents
The following table lists the file contents
Generated Contents Status
3D model Successful
2D front view Successful
2D back view Successful
2D left view Successful
2D right view Successful
2D top view Successful
2D bottom view Successful
Properties
Properties included on publish
Identity Data
Description ClearFire Hot Water Boilerf
Manufacturer CleaverBrooks
Model CFLC-700-12000-160HW OLD
URL
Connectors
Connector properties included on publish
Pipe Connector Connector:1
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Flange
Shape Round
Radius 3.990 in
Description Hot Water Supply
Duct Connector Connector:2
System Type Exhaust
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Slip Joint
Flow Configuration Preset
Flow
Flow Factor
Flow Direction Out
Shape Round
Height 0.000 in
Width 0.000 in
Radius 10.464 in
Description Stack
Pipe Connector Connector:4
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 1.188 in
Description Safety Valve
Pipe Connector Connector:5
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Flange
Shape Round
Radius 3.990 in
Description Low Temperature Return
Pipe Connector Connector:9
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 0.690 in
Description Condensate Drain
Pipe Connector Connector:10
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 0.805 in
Description Boiler Drain
Pipe Connector Connector:11
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Flange
Shape Round
Radius 2.938 in
Description Water Return
Pipe Connector Connector:13
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 1.435 in
Description Gas Supply