Autodesk Inventor Translation Report
|
|
Workflow Type: |
BIM building components |
Number Of Connections: |
8 succeed, 0 fail |
Translation Time: |
0:00:11.000 |
Number Of Faces: |
2575 |
Sending System: |
Inventor 2017.3 |
Complexity Rating: |
High |
Units: |
inch |
Bounding Box Size: |
69.125 in x 125.300 in x 148.611 in |
|
Contents
|
The following table lists the file contents |
|
Generated Contents |
Status |
|
3D model |
Successful |
 |
2D front view |
Successful |
|
2D back view |
Successful |
|
2D left view |
Successful |
|
2D right view |
Successful |
|
2D top view |
Successful |
|
2D bottom view |
Successful |
|
|
Properties
|
Properties included on publish |
|
Identity Data |
|
Description |
ClearFire Hot Water Boilerf |
Manufacturer |
CleaverBrooks |
Model |
CFLC-700-12000-160HW OLD |
URL |
|
|
Connectors
|
Connector properties included on publish |
|
Pipe Connector |
Connector:1 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Flange |
Shape |
Round |
Radius |
3.990 in |
Description |
Hot Water Supply |
|
Duct Connector |
Connector:2 |
System Type |
Exhaust |
Loss Method |
None |
Loss Coefficient |
|
Pressure Drop |
|
Connection Type |
Slip Joint |
Flow Configuration |
Preset |
Flow |
|
Flow Factor |
|
Flow Direction |
Out |
Shape |
Round |
Height |
0.000 in |
Width |
0.000 in |
Radius |
10.464 in |
Description |
Stack |
|
Pipe Connector |
Connector:4 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
1.188 in |
Description |
Safety Valve |
|
Pipe Connector |
Connector:5 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Flange |
Shape |
Round |
Radius |
3.990 in |
Description |
Low Temperature Return |
|
Pipe Connector |
Connector:9 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
0.690 in |
Description |
Condensate Drain |
|
Pipe Connector |
Connector:10 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
0.805 in |
Description |
Boiler Drain |
|
Pipe Connector |
Connector:11 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Flange |
Shape |
Round |
Radius |
2.938 in |
Description |
Water Return |
|
Pipe Connector |
Connector:13 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
1.435 in |
Description |
Gas Supply |
|