Autodesk Inventor Translation Report
Source File: W:\Modular\CFC-E\HW\Inventor\CFC-E-700-750to2000-125HW.ipt
Tuesday, 3/19/2019 (4:17:01 PM)
Published File: W:\Modular\CFC-E\HW\Exports\CFC-E-700-1500-125HW.adsk
Component Type: 23.75.10.11.14.14 Condensing Boilers
Workflow Type: BIM building components Number Of Connections: 10 succeed, 0 fail
Translation Time: 0:00:15.062 Number Of Faces: 2584
Sending System: Inventor 2017.3 Complexity Rating: High
Units: inch Bounding Box Size: 35.800 in x 57.750 in x 79.900 in
Contents
The following table lists the file contents
Generated Contents Status
3D model Successful
2D front view Successful
2D back view Successful
2D left view Successful
2D right view Successful
2D top view Successful
2D bottom view Successful
Properties
Properties included on publish
Identity Data
Description Condensing Boilers
Manufacturer Cleaver-Brooks, Inc.
Model CFC-E-700-1500-125 HW
URL www.cleavrbrooks.com
Connectors
Connector properties included on publish
Pipe Connector Connector:2
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient 0.000 ul
Pressure Drop 0.000 psi
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Bidirectional
Connection Type Brazed
Shape Round
Radius 0.658 in
Description
Pipe Connector Connector:3
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient 0.000 ul
Pressure Drop 0.000 psi
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Bidirectional
Connection Type Brazed
Shape Round
Radius 0.950 in
Description
Pipe Connector Connector:4
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Bidirectional
Connection Type Brazed
Shape Round
Radius 4.000 in
Description
Pipe Connector Connector:5
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient 0.000 ul
Pressure Drop 0.000 psi
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Bidirectional
Connection Type Brazed
Shape Round
Radius 0.830 in
Description
Pipe Connector Connector:6
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Bidirectional
Connection Type Brazed
Shape Round
Radius 2.013 in
Description
Pipe Connector Connector:8
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient 0.000 ul
Pressure Drop 0.000 psi
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Bidirectional
Connection Type Brazed
Shape Round
Radius 2.013 in
Description
Electrical Connector Connector:9
System Type Power - Unbalanced
Description
Voltage
Number of Poles 1
Apparent Load Phase 1
Apparent Load Phase 2
Apparent Load Phase 3
Load Classification
Motor True
Power Factor
Power Factor State Lagging
Electrical Connector Connector:10
System Type Power - Unbalanced
Description
Voltage
Number of Poles 1
Apparent Load Phase 1
Apparent Load Phase 2
Apparent Load Phase 3
Load Classification
Motor True
Power Factor
Power Factor State Lagging
Duct Connector Connector:11
System Type Exhaust
Loss Method None
Loss Coefficient 0.000 ul
Pressure Drop 0.000 Pa
Connection Type Banded
Flow Configuration Preset
Flow
Flow Factor
Flow Direction In
Shape Round
Height
Width
Radius 4.055 in
Description
Pipe Connector Connector:12
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Flange
Shape Round
Radius 2.013 in
Description Water high temp return