Autodesk Inventor Translation Report
Source File: W:\Firetube\CBEX DE\Inventor\CBEX DE-200-250 to 800-150ST.ipt
Thursday, 2/1/2018 (11:52:02 AM)
Published File: W:\Firetube\CBEX DE\Exports\CBEX DE-200-700-150ST.adsk
Component Type: 23.65.35.11.17 Thermodynamic Water Heaters
Workflow Type: BIM building components Number Of Connections: 10 succeed, 0 fail
Translation Time: 0:00:8.313 Number Of Faces: 1384
Sending System: Inventor 2017.3 Complexity Rating: Medium
Units: inch Bounding Box Size: 112.830 in x 117.750 in x 284.900 in
Contents
The following table lists the file contents
Generated Contents Status
3D model Successful
2D front view Successful
2D back view Successful
2D left view Successful
2D right view Successful
2D top view Successful
2D bottom view Successful
Properties
Properties included on publish
Identity Data
Description Firetube
Manufacturer CleaverBrooks
Model CBEX-DE-200-700-150ST
URL www.cleaverbrooks.com
Connectors
Connector properties included on publish
Pipe Connector Connector:1
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 1.500 in
Description Relief Connection
Pipe Connector Connector:2
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 1.500 in
Description Relief Connection
Pipe Connector Connector:4
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 1.188 in
Description Gas Connection
Pipe Connector Connector:5
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Flange
Shape Round
Radius 4.000 in
Description Steam Flange Connection
Electrical Connector Connector:6
System Type Controls
Description Control Panel
Pipe Connector Connector:7
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 1.250 in
Description Feedwater Inlet Connection
Pipe Connector Connector:8
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 1.250 in
Description Feedwater Inlet Connection
Duct Connector Connector:9
System Type Exhaust
Loss Method None
Loss Coefficient
Pressure Drop
Connection Type Slip Joint
Flow Configuration Preset
Flow
Flow Factor
Flow Direction Out
Shape Round
Height 0.000 in
Width 0.000 in
Radius 12.000 in
Description Stack Connection
Pipe Connector Connector:10
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction Out
Connection Type Threaded
Shape Round
Radius 1.188 in
Description Bottom Blowdown
Pipe Connector Connector:11
System Type Other
Allow Slope Adjustment True
Loss Method None
K Coefficient
Pressure Drop
Flow Configuration Preset
Flow Factor
Flow
Flow Direction In
Connection Type Threaded
Shape Round
Radius 1.188 in
Description